home *** CD-ROM | disk | FTP | other *** search
- Path: news.mountain.net!usenet
- From: gene_heskett@wvlink.mpl.com (Gene Heskett)
- Newsgroups: comp.sys.amiga.hardware
- Subject: Re: Help w/external SCSI CDROM/A3000 data errors
- Date: 13 Jan 96 18:35:00 +0500
- Organization: MountainNet, Inc. Morgantown WV 800.444.1458
- Message-ID: <841.6586T1115T35@wvlink.mpl.com>
- References: <rknopDKzInx.CHM@netcom.com>
- NNTP-Posting-Host: slip10.mpl.com
- X-Newsreader: THOR 2.22 (Amiga;TCP/IP)
-
- Pin 26 is the term power connection on the normal 50 pin scsi buss.
- Since you are *probably* talking about the external 25 pin db connector, it
- may be a bit of exercise with a dvm to trace, but its prolly findable
- starting at the 50 pinners pin 26. I don't know about the RENO, but the
- older model 25 also has a dip switch to turn on term power from its end. I
- used that and that was the total end of any data integrity problems. I was
- forced into that by the loss of the so-called terminator in a mail exchange
- of a defective unit. Its worked so good this way that I'm glad they lost
- it!
-
- Cheers
-
- /* Gene Heskett | These opinions are NOT to be */
- /* CE @ WDTV Weston/Clarksburg WV | confused with the official */
- /* <gene_heskett@wvlink.mpl.com> | WDTV managment views */
- #include <std.disclaimer>
-
-
-